Ethyl Maltol as a New Ligand forSpectrophotometricDetermination of Iron Determination of iron
Iranian Journal of Pharmaceutical Sciences,
دوره 3 شماره 2 (2007),
1 April 2007
,
صفحه 101-110
https://doi.org/10.22037/ijps.v3.40351
چکیده
In this study a new simple selective and sensitive spectrophotometric procedurefor determination of Fe(III) is described. It is based on the formation of a coloredcomplex between ferric iron and ethyl maltol, a strong and highly selective ligandfor Fe(III). After mixing sample and reagent, and incubating at the room temperature,Fe(III)-ethyl maltol complex was extracted with different solvents and the absorbancewas measured at 395 nm. The effect of analytical variables, i.e. amount and typeof the reagents, pH, ratio of Fe(III)/ethyl maltol, presence of other ions, etc., in thedetermination of iron were studied. Our findings showed that the optimum wavelengthfor the measurement was 395 nm. The optimum condition for complex formationand determination of Fe(III) were: molar ratio of ethyl maltol/Fe(III) = 6-10; pH =5. The best solvent for extraction was chloroform. Under the recommendedconditions, formation of the complex is completed in less than 2.5 h. Limit of detectionwas found to be 2.5×10-6M of Fe(III). Linear regression (r2=0.9998) was observedover the range of 2.5×10-6to 5×10-4M of the Fe(III) with respect to the complexnominal concentration. Ions commonly associated with iron did not interfere in thepresent method. This is a simple, reproducible, and sensitive method for determinationof Fe(III) in μmolar levels.
- Determination
- Ethyl maltol
- Iron
- Ligand
- Spectrophotometry
ارجاع به مقاله
مراجع
[2]de Jong JTM, den Das J, Bathmann U, StollMHC, Kattner G, Nolting RF, de Baar HJW,Dissolved iron at subnanomolar levels in theSouthern Ocean as determined by ship-boardanalysis. Anal Chim Acta 1998; 377: 113-5.
[3]Willey JD, Kieber RJ, Williams KH, Crozier JS,Skrabal SA, Brooks Avery JRG. Temporal.variability of iron speciation in coastal rainwater.J Atmos Chem2000; 37: 185-205.
[4]Kieber RJ, Skrabal SA, Smith BJ, Willey JD.Organic complexation of Fe (II) and its impact onthe redox cycling of iron in rain. Environ SciTechnol 2005; 39 (6): 1576 -83.
[5]Viollier E, Inglett PW, Hunter K, RoychoudhuryAN, Van Cappellen P. The ferrozine methodrevisited: Fe (II)/Fe (III) determination in naturalwaters. Appl Geochem2000; 15: 785-90.
[6]Ying C, Ding CM, Zhou TZ, Qi DY. Organicsolvent-soluble membrane filters for the precon-centration and spectrophotometric determinationof iron(II) traces in water with Ferrozine.Fresenius J Anal Chem1999; 363: 119-20.
[7]Tokalioglu S, Kartal S, Elci L. Determination of heavy metals and their speciation in lakesediments by flame atomic absorption spectrometry after a four-stage sequential extraction procedure. Anal Chim Acta2000; 413:33-40.
[8]Yan XP, Hendry MJ, Kerrich R. Speciation ofdissolved iron (III) and iron (II) in water by on-line coupling of flow injection. Anal Chem2000;72: 1879-84.
[9]Aldrich AP, van den Berg CMG. Determinationof iron and its redox speciation in seawater usingcatalytic cathodic stripping voltammetry. Electro-analysis1998; 10: 369-73.
[10]Pulido-Tofino P, Barrero-Moreno JM, Pérez-Conde MC. Aflow-through fluorescent sensor todetermine Fe (III) and total inorganic iron. Talanta2000; 51: 537-42.
[11]Schnell S, Ratering S, Jansen KH. Simultaneousdetermination of iron (III), iron (II), andmanganese (II) in environmental samples by ionchromatography. Environ Sci Technol 1998; 32:1530-6.
[12]Deutsch F, Hoffmann P, Ortner HM. Fieldexperimental investigations on the Fe(II) and Fe(III)-content in cloudwater samples. J AtmosChem2001; 40: 87-92.
[13]Lazaro F, Luque-DeCastro MD, Valcarcel M.Integrated retention / spectrophotometric detectionin flow-injection analysis: Determination of ironin water and wine. Anal Chim Acta1989; 219:231-8.
[14]Rakestraw NW, Mahncke HB, Beach EF.Determination of iron in sea water. Ind Eng ChemAnal1936; 8: 136-8.
[15]Cooper LHN. Iron in the sea and in marineplankton. Proc R Soc London B Biol Sci 1935;118: 419-38.
[16]Moss LM, Mellon G. Colorimetric determinationof iron with 2-2'-bipyridyl and with 2-2'-2"-terpyridyl. Indus Engin Chem1942; 14: 862-6.
[17]Stookey LL. Ferrozine-a new spectrophotomet-ric reagent for iron. Anal Chem 1970; 42: 779-85.
[18]Giokas DL, Poleologos EK, Karayannis MI.Speciation of Fe (II) and Fe (III) by the modifiedferrozine method, FIA-spectrophotometry, andflame AAS after cloud-point extraction. JAnalyBioanal Chem2002; 373: 237-43.
[19]Bagheri H, Gholami A, Najafi A. Simultaneouspreconcentration and speciation of iron (II) andiron (III) in water samples by 2-mercaptobenzim-idazole-silica gel sorbent and flow injectionanalysis system. Anal Chim Acta2000; 424: 233-8.
[20]To TB, Nordstom DK, Cunningham KM, Ball JW,McCleskey RB. New method for the directdetermination of dissolved Fe (III) concentrationin acid mine waters. Environ Sci Technol1999;33: 807-15.
[21]Gibbs CR. Characterization and application ofFerrozine iron reagent as a ferrous iron indicator.Anal Chem1976; 48: 1197-2002.
[22]Kononets MY, Pakhomova SV, Rozanov AG,Proskurnin MA. Determination of soluble ironspecies in seawater using Ferrozine. J Anal Chem2002; 57: 586-9.
[23]Blain S, Treguer P. Iron (II) and iron (III)determination in sea water at the nanomolar levelwith selective on-line preconcentration and spec-trophotometric determination. Anal Chim Acta1995; 308: 425-9.[24]Dawson MV, Lyle SJ. Spectrophotometric determination of iron and cobalt with ferrozine and dithizone. Talanta1990; 37: 1189-95.
[25]Siffert C., 1989. PhD Thesis. ETH-Zurich,Switzerland.
[26]Reffitt DM, Burden TJ, Seed PT, Wood J,Thompson RP, Powell JJ. Assessment of ironabsorption from ferric trimaltol. Ann Clin Biochem2000; 37: 457-66.
[27]Dobbin PS, Hider RC, Hall AD, Taylor PD,Sarpong P, Porter JB, Xiao G, van der Helm D.Synthesis, physicochemical properties, and biological evaluation of N-substituted-2-alkyl-3-hydroxy-4(1H)-pyridinones: Orally active ironchelators with clinical potential. J Med Chem1993; 20: 2448-58.
[28]Luo W, Ma YM, Quinn PJ, Hider RC, Liu ZD.Design, synthesis and properties of novel iron(III)-specific fluorescent probes. J Pharm Pharmacol2004; 56: 529-36.
[29]Ingle JD, Wilson AL. Difficulties with determining the detection limit with nonlinear calibration curves in spectrometry. Anal Chem1976; 48: 1641-6.
[30]Fogg AG. Iron determination in biological fluids.Anal Chim Acta1969; 45: 5-11.
[31]Akama Y, Nakai T, Kawamura F, Sunsek K. The cerebrospinal fluid transferring proteins. BiochemJ1978; 25: 287-91.
[32]Taminha B, Jagodic V, Herak MJ. Iron absoption and human disease.Anal Chim Acta1976; 83: 22-7.
- چکیده مشاهده شده: 125 بار
- IJPS_Volume 3_Issue 2_Pages 101-110 (English) دانلود شده: 33 بار